Frequency converter Danfoss 75.0 kW FC101P75KT4E20H3XXXXXXXXXXXXAXBXCXXXXDX order no. 131L9907
zoom_out_map
chevron_left chevron_right
-20%

Frequency converter Danfoss 75.0 kW FC101P75KT4E20H3XXXXXXXXXXXXAXBXCXXXXDX order no. 131L9907

The VLT® HVAC Basic Drive FC 101 frequency converter is designed especially for fans and pumps.

With the right application, it can save up to 50% of energy.

This type of frequency converter is supplied without accessories (control panel, terminal cover, etc.), which must be ordered separately.

€4,723.28

€4,723.28 Tax excluded

€5,904.11 -20%

€4,723.28 tax excluded
Availability on request
new_releases Na dotaz
  • Inquiry for goods
  • Inquiry for goods

    * Required fields

    We will reply as soon as possible, usually within a few hours.

    By submitting the form you agree to the processing of your personal data (read)

    Close or  

    Description

    In addition to the normal functions, it is equipped with various modes and special functions:

    Fire suppression mode
    The fire suppression mode prevents the VLT® HVAC Basic Drive from stopping for self-protection reasons. In this mode, the vital ventilator will continue to operate regardless of control signals, warnings or alarms.
    Fire suppression mode helps keep escape routes smoke-free and ensure safety in stairwells and parking lots by running exhaust fans, smoke extraction and the ability to perform basic service functions.
    The fire suppression mode is clearly marked on the display to avoid confusion.
    When set, the inverter will override its own protection functions and continue to run despite the possibility of permanent damage in the event of overheating or overload. The vital goal is to keep the engine running, even if it means self-destruction.

    Skipping frequencies
    By pressing a few buttons on the control panel, the inverter can be set to exclude the frequency bands in which the connected fans create resonances of the ventilation system. It reduces
    vibrations, sounds and equipment wear.

    V-belt monitoring
    The drive can detect from the rotation speed/current draw that the motor has lost contact with the fan and activate an alarm if the belt is broken.

    Flying start
    The inverter can detect the speed and direction of a freely rotating fan or pump and "catch" it to the correct speed. This feature prevents the device from being forcibly started and destroyed.

    Sleep mode
    When sleep mode is enabled, the inverter automatically detects zero or low flow and stops the motor. The inverter constantly monitors the situation to restart the motor should the load demand increase. This ensures continuous power supply, maximum energy saving, noise reduction and extension of the life of the entire device.

    Data sheet
    Danfoss
    131L9907
    Power supply
    3 x 380-480V ±10%
    Electrical coverage:
    IP20
    Performance:
    75 kW
    Rated current:
    147.0A
    Cabinet dimensions (H x W x D):
    H7 - 550 x 313 x 335 mm
    Digital inputs:
    4 (PNP and NPN logic, 0-24 V), programmable
    Analog inputs:
    2 (0-10V or 0/4-20 mA, scalable)
    Analog outputs:
    2 (0/4-20 mA, programmable)
    Internal power supply:
    10.5 ± 0.5 V (max. 25 mA), 24 ± 0.5 V (max. 100 mA)
    Relay outputs:
    2 programmable, 240 V AC, 2 A; 400V AC, 2A
    Communication protocols:
    BACnet, N2 Metasys, FLN Apogee, FC Protocol, ModBus RTU
    Advice:
    FC101 Basic Drive
    Attachments

    FC_101_uživatelská_příručka

    Uživatelská příručka pro FC101 Basic Drive

    file_download Download (8.06MB)

    FC_101_programovací_příručka_EN

    Programovací příručka pro FC101 Basic Drive (anglicky)

    file_download Download (3.62MB)

    FC101_výběr_EN

    Příručka k výběru typu FC 101 Basic Drive (anglicky)

    file_download Download (690.85KB)

    FC101_stručná_příručka

    Příručka k rychlé instalaci typu FC101 Basic Drive

    file_download Download (4.58MB)

    You might also like
    chat Comments (0)